Medium Voltage Switchgear

Medium Voltage Switchgear

Air-insulated 11 kV switchgear in sheet-metal clad, dust-tight cubicles. Vacuum circuit breakers and load-break switches finished to IEC practice and WAPDA P-44:96.

Voltage class
11 kV, 3-phase, 3-wire, 50 Hz
Current rating
630–2500 A
Rupturing capacity
25 kA
Switching
VCB / LBS

Key Features

  1. Interlocked cubicle

    Sheet-metal clad, dust-tight and vermin-proof, fully interlocked for safe operation.

  2. VCB / LBS switching

    Vacuum circuit breakers and load-break switches with metering and protection.

  3. Insulated copper bus

    Three-phase insulated and tinned copper busbars rated 630 to 2500 A.

Lineup

Voltage class11 kV, 3-phase, 3-wire, 50 Hz
Current rating630–2500 A
Rupturing capacity25 kA
SwitchingVCB / LBS
BusbarsInsulated & tinned copper
FormFree-standing, fully interlocked cubicle
ScopeDesign, manufacture, erection, testing & commissioning

Explore available configurations with our engineering team.

Share duty class and form of assembly — we'll scope the right lineup for your commission.

Request configuration

Downloads

Catalogs, technical data, and certificates — request what you need for this assembly.

  • Catalogs

    Medium Voltage Switchgear — product datasheet

    Request
  • Tech Data

    Medium Voltage Switchgear — technical specification

    Request
  • Certificates

    ISO & type-test documentation

    Request

Markets

Continuity across the commissions we serve.

  • Industrial — Main boards and motor control for factories and process plants that run around the clock.

    Industrial

    Main boards and motor control for factories and process plants that run around the clock.

  • Commercial — Distribution for campuses, high-rises, and building services where uptime is expected.

    Commercial

    Distribution for campuses, high-rises, and building services where uptime is expected.

  • Critical facilities — AMF, synchronizing, and main feeds for hospitals and sites that cannot lose power.

    Critical facilities

    AMF, synchronizing, and main feeds for hospitals and sites that cannot lose power.

  • Power distribution — LT main boards and incomers for substations and plant distribution duties.

    Power distribution

    LT main boards and incomers for substations and plant distribution duties.

  • Data & IT — Dense, serviceable power for IT halls and support plant built for continuous operation.

    Data & IT

    Dense, serviceable power for IT halls and support plant built for continuous operation.

  • Infrastructure — Reliable assemblies for airports, civic buildings, and public services under load.

    Infrastructure

    Reliable assemblies for airports, civic buildings, and public services under load.